Single-Stage Turbines
Features
- Integrally geared turbine design for economical operation.
- Available for extremely high inlet steam pressures/ temperatures and high exhaust pressures.
- Available in horizontal or vertical configuration.
- Axial split casing.
- Typical applications include pump, fan, mill, compressor, and generator drives.
- Full admission inlet casings available.
- Multi-valve inlets available.
- From 5 HP (4 kW) to 6035 HP (4500 kW).
Specifications
| AVT | |||||
|
Max. Power |
Max. Inlet Press.
psig1 (bar) |
Max. Inlet Temp. 0F (0C) |
Max. Exh. Press. psig2 (bar) |
Max. RPM | |
| 4025 (3000kW) | 950 (65) | 1050 (565) | 500 (34) | 13,000 | |
|
Max. Inlet Dia. |
Max. Exh. Dia. in. (mm) |
Casing Design |
Inlet Options | ||
| 10 (250) | 14 (350) | Overhung Wheel | Multi-Valve | ||
| TW | |||||
|
Max. Power |
Max. Inlet Press.
psig1 (bar) |
Max. Inlet Temp. 0F (0C) |
Max. Exh. Press. psig2 (bar) |
Max. RPM | |
| 250 (185kW) | 900 (62) | 1000 (540) | 300 (20) | 6500 | |
|
Max. Inlet Dia. |
Max. Exh. Dia. in. (mm) |
Casing Design |
Inlet Options | ||
| 4 (100) | 8 (200) | Overhung Wheel | Hand Valves | ||